Can You Use an Extension Cord on a Traeger Grill?

 In this brief guide, we will answer the query, “Can You Use an Extension Cord on a Traeger Grill?” and will discuss what type of extension cord is used on a Traeger Grill.

Can You Use an Extension Cord on a Traeger Grill?

Yes, you can use an extension cord on a Traeger Grill. Except for Europe, Traeger claims its pellet grills may safely be used with an extension cable. Due to the short length of the grill’s power cable (approximately 6 1/2 feet), an extension cord is required. Use an outside extension cable with a minimum gauge of 14 if possible.

What’s the best way to power a pellet grill?

Traeger’s, in contrast to conventional grills, must be connected to an electrical outlet. The amount of electricity used is little. However, the thermostat, fan, igniter rod, and auger all need electricity to function.

When you connect it to an outlet, be certain it is turned off. Pellet grills, on the other hand, may be powered by a normal 110-volt home outlet. You’ll be unable to take it anywhere without a generator or inverter, but that’s not a problem.

The auger is powered by the energy generated when you plug it in. The hopper then empties into the firepot, where the wood pellets are fed from there. The wood pellets are then set afire with the help of electricity. Electric fans assist in moving the smoke and heat by creating a circulating airflow. It’s similar to a convection oven in that respect.

To get the most out of your Traeger for the first time, you’ll want to season it first. There is a 50-minute time commitment, but the process is straightforward, and you only have to do it once.

For a Traeger Grill, what gauge extension cord do you need?

Use the smallest possible length of a 12- or 14-gauge extension cable for optimal results. However, there’s more to it than meets the eye. The smallest possible length should be used. Ideally, this distance should be no more than 50 feet. Even better, aim at a distance of 25 feet. Extension cables should not be connected in series.

When two cables are connected, their combined current capacity is reduced, causing the connection to heat up more quickly. Overheating of the cable may harm the cord’s insulation. As a result, electrical fires may begin to spread quickly.

A 15-amp cable with a 3-prong grounding connector is also recommended. It has to be UL-approved and have a W-A mark on it. Tags for outdoor appliances should explicitly indicate that they are “suitable.”

Extension cords with a gauge of 16 or 18 should not be used. As a consequence, your home’s wiring may be damaged, and it may even start a fire. Even though they have a higher gauge number, 16- and 18-gauge cables are still smaller and designed for lightweight use. The heavier the gauge, the lower the number.

It is not only electrical faults that cause fires to ignite. Make sure you have the correct cord and take appropriate safety precautions after that. Keep all connections clean, dry, and as far away from water as possible. Leave nothing dangling that you don’t need people to fall over.

Even a Traeger may catch on fire from time to time.

How to replace a Traeger grill’s power cable? 

 To begin, ensure the cord is disconnected from the wall before attempting to remove the power connection. After that, you’ll have to remove the hopper to get to the cord. Check to see whether the hopper has any pellets and remove them. Remove the screws from the hopper’s control panel and insert the control panel into the hole you have made in the panel.

After that, take out the grill’s hopper by pulling it out of the barrel. There are a total of four screws in this thing. Remove the hopper and set it aside. This reveals the connection to the power cable.

Disconnect the power cord’s black Molex connectors. The ground wire’s screws need to be loosened, so take pliers and squeeze the wire’s retaining piece to release it. Extend the wire by wiggling it out and feeding it through the hole in the wall.

You may now connect your new power cable. If you feed it into the mounting hole, make sure the harness is snapped in place. Then go back and do everything in reverse. Set up the securing element. Ground your system by connecting the appropriate wire to the grounding lug. Reinstall the control panel and the hopper.

That’s all there is to it. It’s a piece of cake. When your Traeger grill is not in use, consider keeping it plugged in. However, there are certain situations in which you should avoid leaving your Traeger plugged in all the time.

Other FAQs about Grills that you may be interested in.

Why Did My Traeger Catch Fire?

Conclusion

In this brief guide, we answered the query, “Can You Use an Extension Cord on a Traeger Grill?” and discussed what type of extension cord is used on a Traeger Grill.

References

https://kitchenappliancehq.com/can-you-use-an-extension-cord-on-a-traeger-grill/

Was this helpful?